首页 供应 求购 产品 公司 登陆

AndoA Q6330光谱分析仪

  • 发布时间:2018-09-17 15:15:37
    报价:面议
    地址:广东,深圳,龙岗区龙城街道爱联社区嶂背一村别墅区一巷三栋
    公司:深圳市福田区鑫民泰仪器行
    手机:13713875417
    微信:szmtyq
    电话:0755-83794885
    用户等级:普通会员 已认证

    AndoAQ6330- Ando AQ6330便携式光谱分析仪

    专业销售/收购/维修、租赁二手仪器设备
    手机:李汉明曾小姐,QQ308966

    Ando AQ6330便携式光谱分析仪

     

    The Ando AQ6330 is a Portable Optical Spectrum Analyzer covering a wavelength range of 1200 to 1700 nm linearity. The AQ6330 has a c o mpact body weighing merely 8 kg. It offers GPIB remote control. For lab application, you might want to consider the Ando AQ6317B.

     

    应用场合:

    光纤放大器,LED, FP-LD and DFB-LD激光器,无源光器件的测试评估

    The AQ6330 is a portable optical spectrum analyzer (OSA) with the high performance required for 50 GHz and 100 GHz DWDM network testing. In both the C and L bands and beyond, wavelength rans is 1200 nm to 1700 nm. The AQ6331 is compact, yet has all the features required for DWDM system evaluation. Further, it has excellent wavelength resolution, with accuracy and dynamic range equal to that of any conventional bench-top OSA used in research and development applications

    The AQ6330 OSA is suitable both for the installation and maintenance of DWDM systems, FTTx or CWDM networks, and for research and development applications.

    Compact and lightweight - Approx. 315 (W) x 200 (H) x 225 (D) mm and only 10 kg., yet comes with a light source for wavelength calibration and a printer as standard features. High wavelength accuracy - Features ±0.02 nm wavelength accuracy at 1520 to 1580 nm and ±0.05 nm accuracy at 1580 to 1620 nm, using an internal light source to perform wavelength calibration. Internal wavelength calibration function - The built-in reference light source eliminates the need for an optical fiber connection to an external light source to perform wavelength calibration. Connection to  the reference light source is done automatically by an internal optical switch. High dynamic range and high wavelength resolution - With dynamic range of 55 dB or more (peak plusmn;0.4 nm) and wavelength resolution of 0.05 nm (min.), 50 GHz channel-spaced DWDM systems can be measured. High power measurement - Optical amplifier output and high output laser diodes in DWDM systems can be measured directly because the measurement level can range up to +20 dBm. Low polarization dependency - Optical amplifier gain can be measured accurately because polarization dependency is as low as ±0.05 dB. Long-term analysis function - Changes to each DWDM channel peak can be measured over time. Convenient programming function - Shortens measurement time because measurement conditions and processes, etc., can be input to memory prior to measurement./li> Individual traces of three wave-forms - Individual traces of three waveforms can be displayed. Can also compare two waveforms - a reference waveform and a measurement result - to determine the difference between the each. Internal high-speed printer