首页 供应 求购 产品 公司 登陆

三菱 塑壳断路器;NF630-SEW 3P 300

  • 发布时间:2020-07-10 00:00:00
    报价:面议
    地址:广东,东莞,东莞市莞城区元岭路国汇大厦320
    公司:东莞市恒轩机电有限公司
    手机:18811829384
    微信:yuqi20175
    电话:0769-33215706
    用户等级:普通会员 已认证

    -630A

    隔离功能

    Isolation function

    隔离功能就是要求断路器断开后的泄漏电流不致对人身和设备产生危害。多次短路跳闸后开关性能下降,泄漏电流会增大。对人体而言30mA以下为安全漏电电流,而在恶劣的环境中,超过300mA的泄漏电流持续2小时以上,就可能使绝缘损坏发生相地短路进而引发火灾。

    The isolation function is that the leakage current after the circuit breaker is broken will not cause harm to the body and equipment. After many times short circuit tripping, the performance of the switch decreases, and the leakage current will increase. For the human body, the less than 30mA is a safe leakage current, and in a bad environment, the leakage current over 300mA lasts more than 2 hours, which may cause the insulation damage to be short circuited and then cause the fire.

    漏电保护

    Leakage protection

    漏电器有热磁式和电子式2种,相比而言电子式漏电器具有体积小、精度高、灵敏度高的优点,但其抗干扰能力较差。目前电子式漏电保护器占据主流,当漏电电流达到整定值时,执行电路接收零序电流互感器二次侧的感应电压信号,驱动转换触点输出漏电保护信号,使脱扣器动作切断电源。

    The leakage electric apparatus has 2 kinds of thermal magnetic and electronic, compared with the small size, high precision, high sensitivity, but its anti-interference ability is poor. At present, the electronic leakage protector occupies the mainstream. When the leakage current reaches the setting value, the utive circuit receives the induction voltage signal on the two side of the zero sequence current transformer, and drives the transfer contact to output the leakage protection signal and makes the tripping device cut off the power supply.

    一般终端开关的整定漏电脱扣电流为30mA、上一级支路开关的整定值为300mA。起火危险性大的电弧性短路难以被短路保护有效切断,而漏电器可以可靠的断开接地故障,防止人身触电和相地短路故障的发生。

    The setting current of the general terminal switch is 30mA and the setting value of the upper branch switch is 300mA. The arc short circuit with high risk of fire is difficult to be cut off effectively by short circuit protection, and the leakage electric apparatus can disconnect the grounding fault reliably, so as to prevent the occurrence of personal electric shock and the fault of the phase to ground short circuit.