首页 供应 求购 产品 公司 登陆

RS-320胸 肺模体

  • 发布时间:2024-11-13 00:00:00
    报价:面议
    地址:广东,深圳,深圳市龙岗区沙平北路111号吉茂大厦608A
    公司:深圳为尔康科技有限公司
    手机:15361860065
    微信:zengxianghu1985
    电话:0755-28896837
    用户等级:普通会员 已认证

    RSD RS-320胸/肺模体,RSD RS-320肺部模体,RSD RS-320胸部模体

    Alderson肺/胸部模体是一个专门的模体,提供高度的现实主义在胸部X光片。肺/胸部模体模型带有可拆卸的隔膜肺对插入物,无冠状动脉。

    RSD RS-320胸/肺模体,RSD RS-320肺部模体,RSD RS-320胸部模体特点和优点

    广泛的血管细节

    不同程度的血管对比可用

    可互换的正常和病理性肺

    从颈部延伸到隔膜下方

    选择动物肺以匹配成年男性的大小。

    允许肺交换,并提供无限数量的配置和疾病模拟。

    肺动脉注射血液当量塑料。

    提供血液当量肺动脉,或添加低或高对比剂。

    RSD RS-320胸/肺模体,RSD RS-320肺部模体,RSD RS-320胸部模体为了证明不同的病理状况,纳入了五种标准病状(可选项目):

    第一个左肋尖端有两个连续的0.5厘米结节

    0.6厘米结节叠加在左下叶大血管

    1.5厘米结节,左侧纵隔阴影

    0.6厘米结节与右肺动脉混合

    肺右下叶

    保修信息:1年保修

    LUNG/CHEST PHANTOMS

    Extensive Vascular Detail

    Different Degrees of Vascular Contrast Available

    Interchangeable Normal and Pathological Lungs

    Developed in conjunction with the University at California, Irvine's Department of Radiological Sciences, the Alderson Lung/Chest Phantom is a specialized phantom, providing a high degree of realism in chest radiography.

    The Alderson Lung/Chest Phantom extends from the neck to below the diaphragm. It is molded about a male skeleton, corresponding to the external body size of a patient, 5 feet, 9 inches (175 cm) tall and weighing

    162 lbs (73.5 kg). RSD materials are equivalent to natural bone and soft tissues.

    Animal lungs are selected to match the size of an adult male. Lungs are fixed in the inflated state and are molded to conform to the pleural cavities of the phantom. The pulmonary arteries are injected with a blood equivalent plastic.

    The Lung/Chest Phantom with simulated left coronary artery reveals several areas of coronary artery irregularity and narrowing.

    To demonstrate different pathological conditions, five standard pathologies are incorporated: Please call for pricing.

    Two contiguous 0.5 cm nodules at the tip of the first left rib.

    A 0.6 cm nodule superimposed with large vessel in the left lower lobe.

    A 1.5 cm nodule, left mediastinal shadow.

    A 0.6 cm nodule blending in with the right pulmonary artery.

    Pneumonia in the right lower lobe.

    The Lung/Chest Phantom is available either with the diaphragm permanently sealed to the interior of the phantom, fixing the lungs in place, or with a removable diaphragm, which permits the interchange of lungs, and provides an unlimited number of configurations and disease simulations.

    Custom pathologies are available as wrap around sheets on either or both lungs.

    All models are available with blood-equivalent pulmonary arteries, or with low or high contrast media added.

    MODEL NUMBERS

    RS-310:Lung/Chest Phantom with permanently sealed diaphragm

    RS-315:Lung/Chest Phantom with permanently sealed diaphragm and left coronary artery

    RS-320:Lung/Chest Phantom with removeable diaphragm lung pair insert without coronary artery

    RS-330:Lung/Chest Phantom with removeable diaphragm lung pair insert with coronary artery

    RS-340:Lung/Pair insert without coronary artery

    RS-345:Lung/Pair insert with coronary artery