首页 供应 求购 产品 公司 登陆

DyniscoCMR连续式熔融流变仪

  • 发布时间:2021-02-19 15:48:29
    报价:面议
    地址:上海,松江,上海松江区车墩镇联营路615号18幢6楼
    公司:齐亚斯(上海)联网科技有限公司
    手机:15026617481
    微信:onlinexiang
    用户等级:普通会员 已认证
    在线流变仪,连续性检测,包含毛细管流变仪所有的性能   它能够满足每天需24小时连续操作的要求, 程度地保持高精确度、高可重复性和高灵敏度。 

    Several options complete the broad
    application range of the CMR series
    of Online Rheometers.
    Different capillaries allow the user
    to measure Melt Flow Index or
    apparent viscosity.
    Stand for RCU
    Process Isolation valve
    Heated transfer section
    Hazardous location
    Additional I/O
    NEMA 4X
    Performance Specifications:
    Melt Flow Index 0.02 – 5000 g/10 min
    Viscosity Range 10 – 105 Pa s
    Shear stress 150 – 1.5 x 105 Pa
    Shear rate 1 – 7500 s-1 (standard die)
    max. 50 000 s-1 (special die)
    Capillary dies:
    Viscosity: ­ 1 – 5 mm, 10:1 to 30:1 L/D
    Melt Flow Index:­ per melt flow, 3.8182 L/D
    Special dies upon request
    Temp.-range 40 – 350 °C
    Pressure range psi (3 x 105– 3.5 x 107 Pa)
    Metering pump 0.16 cm3/rpm (standard)
    optional sizes available
    Pump speed 3 – 75 rpm
    Polymer Flow 1/2 lbs/hr (225 g/hr) avg.
    Measurement and Control Functions:
    Test Modes
    Shear Stress Mode:
    Setpoint: Pressure
    Measurement: Melt Flow Index
    Shear Rate Mode:
    Set point: Pump speed
    Measurement: Apparent viscosity
    Temp. control 3 Heating zones
    Specifications:
    Electr. Cabinet NEMA 4 (IP 54)
    CPU 80188 E-PROM Embedded Applications
    Program
    Operator Interface Nematron LCD display
    Analog Outputs: (4-20mA standard)
    Standard Melt Flow Index or
    apparent viscosity
    Optional Melt temperature
    Melt pressure
    Pump speed
    Temp. pump zone
    Temp. die zone
    Digital Inputs: (NO/NC dry contacts)
    RemoteTest ON/OFF (Motor Start / Stop)
    Digital Outputs: (NO/NC)
    Fault Shuts down analyzer and
    requires manual restart
    Warning Information / Deviation Alarms
    Analyzer continues to operate
    Serial Output: RS standard
    Electrical Specification:
    System voltage 115 or 230 VAC 50/60 HZ
    Power consumt. 2000 W (max)
    Depending on the installation requirements
    the rheometer as well as
    the RCU is available as general
    purpose version or for hazardous
    locations.
    Different gear pumps give the
    possibility to adjust to the needed polymer
    flow.
    The RCU control cabinet is available
    as wall mounted version or with free
    standing console (option).

    DyniscoCMR连续式熔融流变仪